{
 "uuid": "a354760f-39ca-441d-8a19-8a3c866c46ba",
 "handle": "uniba/46257",
 "type": "Publication",
 "name": "Gibt es einen Unterschied in der glykämischen Kontrolle zwischen erfahrenen und neuen Nutzern von Flash Glukose Monitoring?",
 "url": "/entities/publication/a354760f-39ca-441d-8a19-8a3c866c46ba/",
 "lastModified": "2024-10-15T15:23:02.682+00:00",
 "metadata": {
  "cris.virtual.author-orcid": [
   {
    "value": "0000-0002-2903-2677"
   },
   {
    "value": "0000-0002-5794-5596"
   },
   {
    "value": null
   },
   {
    "value": null
   },
   {
    "value": null
   }
  ],
  "cris.virtualsource.author-orcid": [
   {
    "value": "7a9e2901-6807-4dc8-a988-4381abc8d2b2"
   },
   {
    "value": "92a96cad-c405-4bc7-9c4f-46952ba44dee"
   },
   {
    "value": "28e50e71-2d0b-449f-8157-a1d5d5ec565a"
   },
   {
    "value": "6b525df0-e06e-4b58-8cf8-0fb0cf6302f7"
   },
   {
    "value": "d3c8f32a-45af-4bc9-8104-bac23b964410"
   }
  ],
  "dc.contributor.author": [
   {
    "value": "Hermanns, Norbert",
    "authority": "7a9e2901-6807-4dc8-a988-4381abc8d2b2",
    "language": "de_DE"
   },
   {
    "value": "Ehrmann, Dominic",
    "authority": "92a96cad-c405-4bc7-9c4f-46952ba44dee",
    "language": "de_DE"
   },
   {
    "value": "Schipfer, Melanie",
    "authority": "28e50e71-2d0b-449f-8157-a1d5d5ec565a",
    "language": "de_DE"
   },
   {
    "value": "Haak, Thomas",
    "authority": "6b525df0-e06e-4b58-8cf8-0fb0cf6302f7",
    "language": "de_DE"
   },
   {
    "value": "Kulzer, Bernhard",
    "authority": "d3c8f32a-45af-4bc9-8104-bac23b964410",
    "language": "de_DE"
   }
  ],
  "dc.date.accessioned": [
   {
    "value": "2019-09-19T16:17:47Z",
    "language": "de_DE"
   }
  ],
  "dc.date.available": [
   {
    "value": "2019-08-26",
    "language": "de_DE"
   }
  ],
  "dc.date.issued": [
   {
    "value": "2018",
    "language": "de_DE"
   }
  ],
  "dc.description.abstract": [
   {
    "value": "Fragestellung:\r\n\r\nIn einer randomisierten kontrollierten Studie zur Überprüfung eines neu entwickelten Schulungs- und Behandlungsprogramms (FLASH) wurden erfahrene und unerfahrene Nutzer von Flash Glukose Monitoring (FlashGM) eingeschlossen. In dieser deskriptiven Auswertung wurden Baseline-Daten von Teilnehmern, die FlashGM schon vor Beginn der Studie nutzten, verglichen mit Daten von Teilnehmern, die FlashGM erstmalig im Rahmen dieser Studie verwendeten.\r\n\r\nMethode:\r\n\r\nVon insgesamt 216 Studienteilnehmern, benutzten 133 FlashGM bereits vor der Studie, während 83 Probanden bis dahin keine Erfahrungen mit FlashGM hatten. Vor Beginn der Baseline-Erhebung wurde der HbA1c-Wert bestimmt (Zentrallabor), danach trugen die Teilnehmer für 14 Tage das FlashGM zur Baselineerhebung.\r\n\r\nErgebnisse:\r\n\r\nDer HbA1c-Wert war zwischen beiden Gruppen vergleichbar (8,4 ± 1,0% vs. 8,4 ± 0,9%; p = 0,89). Nach 2 Wochen wiesen Probanden, die FlashGM neu nutzten einen niedrigeren mittleren Glukosewert auf als erfahrene Nutzer (179,6 ± 25,9 mg/dl vs. 192,3 ± 39,2 mg/dl; p = 0,005). Neue Nutzer des FlashGM wiesen zur Baseline eine signifikant längere Zeit in der Normoglykämie („time in range“ 71 – 180 mg/dl: 716,5 ± 174,1 vs. 660,2 ± 209,2 Min/Tag; p = 0,036) und weniger hyperglykämische Werte (> 180 mg/dl: 656,0 ± 194,0 vs. 715,0 ± 232,8 Min/Tag; p = 0,048) auf als erfahrene Nutzer dieses Systems, während sich die beiden Gruppen hinsichtlich der Dauer hypoglykämischer Phasen (≤70 mg/dl) nicht unterschieden (69,3 ± 52,0 vs. 67,9 ± 52,9 Min/Tag; p = 0,85).\r\n\r\nSchlussfolgerung:\r\n\r\nÜberraschenderweise wiesen Personen die bereits FlashGM benutzten keinen niedrigeren HbA1c-Wert auf als Neunutzer. Ebenso wiesen sie auch keine Vorteile bzgl. der Dauer der normo- und hyperglykämischen Phasen zur Baseline auf. Beide Gruppen könnten demnach von einem strukturierten Schulungs- und Behandlungsprogramm profitieren.",
    "language": "de_DE"
   }
  ],
  "dc.identifier.doi": [
   {
    "value": "10.1055/s-0038-1641974"
   }
  ],
  "dc.identifier.issn": [
   {
    "value": "1861-9002",
    "language": "de_DE"
   }
  ],
  "dc.identifier.uri": [
   {
    "value": "https://fis.uni-bamberg.de/handle/uniba/46257"
   }
  ],
  "dc.identifier.url": [
   {
    "value": "https://www.thieme-connect.com/products/ejournals/abstract/10.1055/s-0038-1641974"
   }
  ],
  "dc.language.abstract": [
   {
    "value": "deu",
    "language": "de_DE"
   }
  ],
  "dc.language.iso": [
   {
    "value": "deu",
    "language": "de_DE"
   }
  ],
  "dc.language.title": [
   {
    "value": "deu",
    "language": "de_DE"
   }
  ],
  "dc.publisher": [
   {
    "value": "Thieme",
    "language": "de_DE"
   }
  ],
  "dc.publisher.place": [
   {
    "value": "Stuttgart [u.a.]",
    "language": "de_DE"
   }
  ],
  "dc.relation.authororgunit": [
   {
    "value": null,
    "authority": "#PLACEHOLDER_PARENT_METADATA_VALUE#",
    "language": "de_DE"
   },
   {
    "value": null,
    "authority": "#PLACEHOLDER_PARENT_METADATA_VALUE#",
    "language": "de_DE"
   },
   {
    "value": null,
    "authority": "#PLACEHOLDER_PARENT_METADATA_VALUE#",
    "language": "de_DE"
   },
   {
    "value": null,
    "authority": "#PLACEHOLDER_PARENT_METADATA_VALUE#",
    "language": "de_DE"
   },
   {
    "value": null,
    "authority": "#PLACEHOLDER_PARENT_METADATA_VALUE#",
    "language": "de_DE"
   }
  ],
  "dc.relation.volume": [
   {
    "value": "13",
    "language": "de_DE"
   }
  ],
  "dc.subject.ddc": [
   {
    "value": "150",
    "language": "de_DE"
   }
  ],
  "dc.title": [
   {
    "value": "Gibt es einen Unterschied in der glykämischen Kontrolle zwischen erfahrenen und neuen Nutzern von Flash Glukose Monitoring?",
    "language": "de_DE"
   }
  ],
  "dc.type": [
   {
    "value": "conferenceobject",
    "language": "de_DE"
   }
  ],
  "dspace.entity.type": [
   {
    "value": "Publication"
   }
  ],
  "ubg.accessRights.copyright": [
   {
    "value": "0",
    "language": "de_DE"
   }
  ],
  "ubg.faculty.org": [
   {
    "value": "Lehrstuhl für Klinische Psychologie/Psychotherapie",
    "authority": "52dbf641-4c1f-4f7c-a0de-a534acadb0fe",
    "language": "de_DE"
   }
  ],
  "ubg.fulltexticon": [
   {
    "value": "true"
   }
  ],
  "ubg.generated.csl": [
   {
    "value": "<div class=\"csl-bib-body\">\n  <div class=\"csl-entry\">Hermanns, Norbert; Ehrmann, Dominic; Schipfer, Melanie; u. a. (2018): Gibt es einen Unterschied in der glykämischen Kontrolle zwischen erfahrenen und neuen Nutzern von Flash Glukose Monitoring?, in: <i>Diabetologie und Stoffwechsel</i>, Stuttgart [u.a.]: Thieme, S. S73 (P216), doi: 10.1055/s-0038-1641974.</div>\n</div>"
   }
  ],
  "ubg.generated.cslContainerTitle": [
   {
    "value": "Diabetologie und Stoffwechsel",
    "language": "de_DE"
   }
  ],
  "ubg.generated.cslDoi": [
   {
    "value": "10.1055/s-0038-1641974"
   }
  ],
  "ubg.intern.opusdatepublished": [
   {
    "value": "2019-08-26"
   }
  ],
  "ubg.intern.org": [
   {
    "value": "Lehrstuhl für Klinische Psychologie/Psychotherapie",
    "authority": "52dbf641-4c1f-4f7c-a0de-a534acadb0fe",
    "language": "de_DE"
   }
  ],
  "ubg.intern.vonfeld": [
   {
    "value": "",
    "language": "de_DE"
   }
  ],
  "ubg.intern.vonfeldeditor": [
   {
    "value": "",
    "language": "de_DE"
   }
  ],
  "ubg.internatorientation": [
   {
    "value": "Nein",
    "language": "de_DE"
   }
  ],
  "ubg.openaccess": [
   {
    "value": "Nein",
    "language": "de_DE"
   }
  ],
  "ubg.pages.range": [
   {
    "value": "S73 (P216)"
   }
  ],
  "ubg.peerreview": [
   {
    "value": "Ja",
    "language": "de_DE"
   }
  ],
  "ubg.relation.issue": [
   {
    "value": "Suppl. 1",
    "language": "de_DE"
   }
  ],
  "ubg.subject.gndsw": [
   {
    "value": "Diabetologie ; Diabetes mellitus ; Flash glucose monitoring ; Erfahrung ; Therapieerfolg",
    "language": "de_DE"
   }
  ],
  "ubg.subject.rvk": [
   {
    "value": "YC 6400",
    "language": "*"
   },
   {
    "value": "YC 6800",
    "language": "*"
   }
  ],
  "ubg.submission.type": [
   {
    "value": "full-text",
    "language": "de_DE"
   }
  ],
  "ubg.titleparent.journal": [
   {
    "value": "Diabetologie und Stoffwechsel",
    "language": "de_DE"
   }
  ],
  "ubg.version.hasversions": [
   {
    "value": "uniba/46999",
    "authority": "c576ac3f-e3e5-4652-8fbb-7bead181a157"
   }
  ]
 },
 "relations": {},
 "files": []
}