@article{kulzer2018_45111,
  title = {Efficacy of an Education Program for People With Diabetes and Insulin Pump Treatment (INPUT): Results From a Randomized Controlled Trial},
  author = {Kulzer, Bernhard and Schipfer, Melanie and Lippmann-Grob, Bernhard and Haak, Thomas and Hermanns, Norbert and Ehrmann, Dominic},
  year = {2018},
  journal = {Diabetes Care},
  volume = {41},
  number = {12},
  pages = {2453-2462},
  address = {Alexandria, Va.},
  issn = {0149-5992},
  doi = {10.2337/dc18-0917},
  url = {https://fis.uni-bamberg.de/handle/uniba/45111},
  language = {eng},
  abstract = {OBJECTIVE Continuous subcutaneous insulin infusion (CSII) is the most advanced form of insulin delivery, but it requires structured education to provide users with the necessary knowledge/skills and to support their motivation. Currently, no structured education program designed to provide this training has been evaluated. We developed a CSII-specific, structured education program (Insulin Pump Treatment [INPUT]) and evaluated its impact on glycemic control, behavior, and psychosocial status.

RESEARCH DESIGN AND METHODS This was a multicenter, randomized, parallel trial with a 6-month follow-up. Eligible participants (age 16–75 years) currently were treated with insulin pump therapy. Participants were randomly assigned (1:1) to the INPUT program or to usual care using a computer-generated algorithm, with study center as the stratification factor. The primary outcome was HbA1c change from baseline to 6 months. Secondary outcomes were incidence of severe hypoglycemia and changes in behavioral and psychosocial measures.

RESULTS Between 1 April 2016 and 26 April 2016, 268 people with diabetes and a mean duration of CSII therapy of 9.5 years were randomly assigned to the INPUT group (n = 135) or control group (n = 133). At 6 months, HbA1c improved in the INPUT group (8.33 ± 0.8 vs. 8.04 ± 0.9; P < 0.0001) but not in the control group (8.33 ± 1.0 vs. 8.27 ± 1.0; P = 0.11). The between-group difference in HbA1c reduction was significant, favoring INPUT (−0.28\% vs. −0.06\%, Δ −0.22\%, 95\% CI −0.38 to −0.06; P = 0.0029). The incidence rate ratio of severe hypoglycemia was 3.55 times higher for participants in the control group than for those in the INPUT group (95\% CI 1.50–8.43; P = 0.0041).

CONCLUSIONS The INPUT education program led to a significant improvement in glycemic control and incidence of severe hypoglycemia in insulin pump users.},
  keywords = {Diabetes, Psychoedukation, Education}
}