Skip to content

Read-only version: For security reasons, the Research Information System (FIS) has been temporarily replaced by this read-only version. All public content and full texts remain available; login, editing, submission and statistics are not available. Questions: fis@uni-bamberg.de

Home › Publications › Wearable inertial sensors are highly sensitive in the detection of gait disturbances and fatigue at early stages of multiple sclerosis

Publication

Wearable inertial sensors are highly sensitive in the detection of gait disturbances and fatigue at early stages of multiple sclerosis

Müller, Roy; Hamacher, Daniel; Hansen, Sascha; u. a. (2025): Wearable inertial sensors are highly sensitive in the detection of gait disturbances and fatigue at early stages of multiple sclerosis, in: Bamberg: Otto-Friedrich-Universität, S. 1–8.

Details

Faculty/Chair
Faculty/Professorship
Author
Müller, Roy
Hamacher, Daniel
Hansen, Sascha
Oschmann, Patrick
Keune, Philipp M.
Publisher Information
Otto-Friedrich-Universität : Bamberg
Year of publication
2025
Source/Other editions
BMC Neurology, Berlin ; Heidelberg: Springer, 2021, Jg. 21, Nr. 1, S. 1–8, ISSN: 1471-2377
Year of first publication
2021
Language
English
Licence
URN
Abstract

Background: The aim of the current study was to examine multiple gait parameters obtained by wearable inertial sensors and their sensitivity to clinical status in early multiple sclerosis (MS). Further, a potential correlation between gait parameters and subjective fatigue was explored.

Methods: Automated gait analyses were carried out on 88 MS patients and 31 healthy participants. To measure gait parameters (i.e. walking speed, stride length, stride duration, duration of stance and swing phase, minimal toeto-floor distance), wearable inertial sensors were utilized throughout a 6-min 25-ft walk. Additionally, self-reported subjective fatigue was assessed.

Results: Mean gait parameters consistently revealed significant differences between healthy participants and MS patients from as early as an Expanded Disability Status Scale (EDSS) value of 1.5 onwards. Further, MS patients showed a significant linear trend in all parameters, reflecting continuously deteriorating gait performance throughout the test. This linear deterioration trend showed significant correlations with fatigue.

Conclusions: Wearable inertial sensors are highly sensitive in the detection of gait disturbances, even in early MS, where global scales such as the EDSS do not provide any clinical information about deviations in gait behavior. Moreover, these measures provide a linear trend parameter of gait deterioration that may serve as a surrogate marker of fatigue. In sum, these results suggest that classic timed walking tests in routine clinical practice should be replaced by readily and automatically applicable gait assessments, as provided by inertial sensors.

Keywords
Multiple sclerosis (MS)
6-min walk
25 foot walk
toe clearance
motor fatigue
EDSS
DDC Classification
610 Medicine & health
RVK Classification
YG 6000
Type
Article
URI
Activation date
2025-12-17

Permalink: https://fis.uni-bamberg.de/handle/uniba/110882 · Data as JSON · Cite: BibTeX · RIS

Data as of: 2026-11-15

Restricted read-only access: login, editing and submission are temporarily disabled.