Home › Publications › Heat pump inspections result in large energy savings when a pre-selection of households is performed : A promising use case of smart meter data

Publication

Heat pump inspections result in large energy savings when a pre-selection of households is performed : A promising use case of smart meter data

Weigert, Andreas; Hopf, Konstantin; Günther, Sebastian A.; u. a. (2022): Heat pump inspections result in large energy savings when a pre-selection of households is performed : A promising use case of smart meter data, in: Energy Policy, Amsterdam [u.a.]: Elsevier, Jg. 169, Nr. 113156, S. 1–15, doi: 10.1016/j.enpol.2022.113156.

Details

Faculty/Chair
Faculty/Professorship
Author
Weigert, Andreas
Hopf, Konstantin
Günther, Sebastian A.
Title of the Journal
Energy Policy
ISSN
0301-4215
Publisher Information
Elsevier : Amsterdam [u.a.]
Year of publication
2022
Volume
169
Issue
113156
Language
English
DOI
Abstract

Heat pumps play an important role in the energy transition. They can extract renewable energy from the air or ground and increasingly replace fossil heating systems in buildings. In operation, however, heat pumps often consume more electricity than necessary due to incorrect settings and installation deficiencies. Although many setting and installation issues are easy to fix, problems often go unnoticed, and the saving potential from quick fixes remains unclear. In a study with 297 Swiss households (41 treatment, 256 control) running for four years, we investigated an energy efficiency campaign in which the treatment group received a professional heat pump inspection and user training. We found considerable heterogeneity with respect to the savings achieved. We derived two criteria based on smart meter data that enable utilities to identify relevant households and thus boost the impact of such efficiency campaigns: For example, pre-selecting half of the households based on available information results in average savings of 1,805 kWh (15.2%) per year and household in the high-potential group compared to no savings in the low-potential group. Thus, heat pump inspections among pre-selected households can lead to large, cost-effective electricity savings, and we show that common smart meter data makes such pre-selection feasible.

GND Keywords
Wärmepumpe
Energieeffizienz
Energieberatung
Intelligenter Zähler
Datenanalyse
Keywords
Heat pump
Energy consulting
Energy efficiency
Smart meter data
Data analytics
DDC Classification
333.7 Natural ressources, energy, environment
RVK Classification
ST 530
Peer Reviewed
yes
International Distribution
yes
Type
Article
URI
Activation date
2022-08-26
Project(s)

Permalink: https://fis.uni-bamberg.de/handle/uniba/55315 · Data as JSON · Cite: BibTeX · RIS

Data as of: 2026-11-16

Restricted read-only access: login, editing and submission are temporarily disabled.