Skip to content

Read-only version: For security reasons, the Research Information System (FIS) has been temporarily replaced by this read-only version. All public content and full texts remain available; login, editing, submission and statistics are not available. Questions: fis@uni-bamberg.de

Home › Publications › Stability of sensor-based gait parameters reassessed after a period of one year in people with multiple sclerosis

Publication

Stability of sensor-based gait parameters reassessed after a period of one year in people with multiple sclerosis

Müller, Roy; Hamacher, Daniel; Keune, Philipp M.; u. a. (2025): Stability of sensor-based gait parameters reassessed after a period of one year in people with multiple sclerosis, in: Bamberg: Otto-Friedrich-Universität, S. 1–8, doi: 10.1186/s12883-023-03168-9.

Details

Faculty/Chair
Faculty/Professorship
Author
Müller, Roy
Hamacher, Daniel
Keune, Philipp M.
Oschmann, Patrick
Publisher Information
Otto-Friedrich-Universität : Bamberg
Year of publication
2025
Source/Other editions
BMC neurology, London: BioMed Central, 2023, Jg. 23, Nr. 120, S. 1–8, ISSN: 1471-2377
Year of first publication
2023
Language
English
Licence
DOI
Abstract

Background:

Currently, there are several studies showing that wearable inertial sensors are highly sensitive in the detection of gait disturbances in people with multiple sclerosis (PwMS), showing excellent reliability within one or 7–14 days. However, it is not known how stable these gait parameters remain over a longer period of time. This is surprising, because many treatments last longer than two weeks. Thus, the purpose of the current study was to examine gait parameters obtained by means of wearable inertial sensors during a 6-min walk and to reassess these parameters after a period of one year.

Methods:

Fifty PwMS (without a relapse or a recent change in the Expanded Disability Status Scale (EDSS) or treatment) and 20 healthy participants were examined at two assessment points (interval between assessments: 14.4 ± 6.6 months). At each assessment point, all participants had to complete a 6-min walking test, an observer-rater test (Berg Balance Scale, BBS) and a Timed-up and Go Test (TUG). To measure mean gait parameters (i.e. walking speed, stride length, stride time, the duration of the stance and swing phase and minimum toe-to-floor distance), as well as the intraindividual standard deviation of each mean gait parameter, wearable inertial sensors were utilized.

Results:

We found that even after one year all mean gait parameters showed excellent Intraclass Correlation Coefficients (ICC between 0.75 and 0.95) in PwMS. Looking at MS subgroups, the ICCs were slightly higher in MS subgroup 2 (EDSS 2.0–5.0) than those in MS subgroup 1 (EDSS 0.0–1.5) and healthy controls. Compared to the mean gait parameters, parameters of gait variability showed only good-to-fair ICC values in PwMS. Concerning BBS and TUG, the ICC values after one year were close to the ICC values of the measured mean gait parameters.

Conclusions:

Due to the excellent stability of mean gait parameters after one year, these sensor-based gait parameters can be identified as clinically relevant markers to evaluate treatment effects over a longer (several months) period of time in MS.

GND Keywords
Multiple Sklerose
Gangstörung
Keywords
Gait
Reliability
Inertial sensors
MS
6-min walk
EDSS
DDC Classification
150 Psychology
RVK Classification
CZ 1360
Type
Article
URI
Activation date
2025-09-08

Permalink: https://fis.uni-bamberg.de/handle/uniba/109862 · Data as JSON · Cite: BibTeX · RIS

Data as of: 2026-11-16

Restricted read-only access: login, editing and submission are temporarily disabled.