Skip to content

Read-only version: For security reasons, the Research Information System (FIS) has been temporarily replaced by this read-only version. All public content and full texts remain available; login, editing, submission and statistics are not available. Questions: fis@uni-bamberg.de

Home › Publications › Performance and outcome of zirconia dental implants in clinical studies : A meta-analysis

Publication

Performance and outcome of zirconia dental implants in clinical studies : A meta-analysis

Roehling, Stefan; Schlegel, Karl A; Wölfler, Henriette Engelhardt-; u. a. (2025): Performance and outcome of zirconia dental implants in clinical studies : A meta-analysis, in: Bamberg: Otto-Friedrich-Universität, S. 135–153.

Details

Faculty/Chair
Faculty/Professorship
Author
Roehling, Stefan
Schlegel, Karl A
Gahlert, Michael
By
... ; Wölfler, Henriette Engelhardt-; ...
Publisher Information
Otto-Friedrich-Universität : Bamberg
Year of publication
2025
Source/Other editions
Clinical oral implants research, Oxford: Wiley-Blackwell, 2018, Jg. 29, Nr. S16, S. 135–153, ISSN: 0905-7161
Year of first publication
2018
Language
English
Licence
URN
Abstract

Objectives

To evaluate implant survival, peri-implant marginal bone loss, technical, and biological complications as well as aesthetic outcomes of zirconia implants in clinical studies.

Material and Methods

Electronic (Medline, Embase) and hand searches were performed to identify clinical studies published between January 2004 and March 2017 investigating zirconia dental implants with a mean follow-up of at least 12 months. Primary outcomes were implant survival and peri-implant marginal bone loss. Secondary outcomes included technical and biological complications as well as aesthetic outcomes. Meta-analyses were performed to estimate implant survival and marginal bone loss.

Results

From 943 titles, 264 abstracts were selected. Subsequently, 80 full-text articles were screened, and 18 studies were included for data extraction. One- (14 studies) and 2-piece zirconia implants (4 studies) were investigated. Commercially available (CA) (510 implants, 398 patients) and not commercially available (NCA) zirconia implants (618 implants, 343 patients) were identified. For CA implants (follow-up: 12–61.20 months), technical complications (1.6%), implant fractures (0.2%) and biological complications (4.2%) were reported. Meta-analyses estimated 1- and 2-year survival rates of 98.3% (95% CI: 97.0%–99.6%) and 97.2% (95% CI: 94.7%–99.7%), respectively, and a mean 1-year marginal bone loss of 0.7 mm (95% CI: 0.4–1.0 mm).

Conclusions

Since 2004, the survival rates of CA implants significantly improved compared with NCA implants. CA 1-piece zirconia implants showed similar 1- and 2-year mean survival rates and marginal bone loss after 1 year compared with published data for titanium implants. However, more clinical long-term data are needed to confirm the presently evaluated promising short-term outcomes.

GND Keywords
Zahnimplantat
Keywords
biological complications; dental implants; aesthetics; implant survival; marginal bone loss; meta-analysis; prosthetics; soft tissue; technical complications; yttria stabilized tetragonal zirconia; zirconium oxide
DDC Classification
610 Medicine & health
RVK Classification
YP 5500
Peer Reviewed
yes
International Distribution
yes
Type
Article
URI
Activation date
2025-08-25

Permalink: https://fis.uni-bamberg.de/handle/uniba/109577 · Data as JSON · Cite: BibTeX · RIS

Data as of: 2026-11-16

Restricted read-only access: login, editing and submission are temporarily disabled.