Zum Inhalt springen

Nur-Lesen-Fassung: Das Forschungsinformationssystem (FIS) ist aus Sicherheitsgründen vorübergehend durch diese Nur-Lesen-Fassung ersetzt. Alle öffentlichen Inhalte und Volltexte sind weiterhin abrufbar; Anmeldung, Bearbeitung, Einreichung und Statistiken stehen nicht zur Verfügung. Bei Fragen: fis@uni-bamberg.de

Start › Publikationen › Change in the usage of pump features predicts improvement of glycemic control

Publikation

Change in the usage of pump features predicts improvement of glycemic control

Ehrmann, Dominic; Hermanns, Norbert; Schipfer, Melanie; u. a. (2017): Change in the usage of pump features predicts improvement of glycemic control, in: Diabetes : a journal of the American Diabetes Association, Jg. 66, Nr. Suppl. 1, S. A274 (1040-P).

Details

Fakultät/Lehrstuhl
Autorin(nen)/Autor(en)
Schipfer, Melanie
Lippmann-Grob, Bernhard
Haak, Thomas
Titel der Zeitschrift
Diabetes : a journal of the American Diabetes Association
ISSN
0012-1797
Herausgebende Institution
ADA Scientific Sessions, 77th, 2017, San Diego, California, USA
Erscheinungsjahr
2017
Jahrgang
66
Heft
Suppl. 1
Sprache(n)
Englisch
Abstract

Insulin pumps offer a wide range of technical features designed to help patients with achieving optimal glycemic control. However, many patients do not achieve better glycemic control despite CSII therapy. In this study, we analyzed whether a change in using pump features was associated with an improvement in glycemic control. 197 patients with CSII treatment were analyzed at baseline and 12-weeks later (age 42.2 ± 14.3 yrs.; 59% female; diabetes duration 22.2 ± 11.9 yrs.; duration of CSII 9.4 ± 7.3 yrs.; baseline A1c 8.3 ± 0.9%). Change in using pump features (see table) were the independent variables of interest in a linear regression analysis on the difference in HbA1c (follow-up – baseline).<cr><nl>

The analysis was controlled for demographic (age, gender, BMI, education) and medical variables (diabetes duration, duration of CSII, use of CGM/FGM, complications, SMBG).<cr><nl>

Increased use of pump features standardized beta p<cr><nl>

Temporary basal rates -0.16 .027<cr><nl>

Different basal rate profiles -0.09 .219<cr><nl>

Bolus options 0.16 .031<cr><nl>

Bolus calculators 0.02 .790<cr><nl>

Analysis software -0.16 .025<cr><nl>

CGM pairing -0.23 .002<cr><nl>

An increased use of temporary basal rates as well as using analysis software more often predicted an improvement in HbA1c (see table). Linking a CGM system to the insulin pump was the strongest predictor of better glycemic control. In clinical practice, patients with CSII therapy should be educated how to make use of their pump features and should be encouraged to do so.

Peer Reviewed
ja
Internationale Verbreitung
ja
Open-Access-Zeitschrift
nein
Dokumenttyp
Artikel in einer Zeitschrift / Postprint
URI
Datum der Freischaltung
02.08.2018, 02.08.2018

Permalink: https://fis.uni-bamberg.de/handle/uniba/44297 · Daten als JSON · Zitieren: BibTeX · RIS

Datenstand: 16.11.2026

Eingeschränkter Lesezugriff: Anmeldung, Bearbeitung und Einreichung sind vorübergehend deaktiviert.