Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement : an in vitro study
Reiff, Florian Sebastian; Bischoff, Charlotte; Woelfler, Henriette; u. a. (2024): Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement : an in vitro study, in: Oral and Maxillofacial Surgery, Berlin ; Heidelberg: Springer, Jg. 28, Nr. 4, S. 1491–1500, doi: 10.1007/s10006-024-01269-4.
Details
- Fakultät/Lehrstuhl
- Autorin(nen)/Autor(en)
- Reiff, Florian SebastianBischoff, CharlotteRoehling, Stefan
- Von
- ... ; Woelfler, Henriette; ...
- Titel der Zeitschrift
- Oral and Maxillofacial Surgery
- ISSN
- 1865-1569
- Verlagsangabe
- Springer : Berlin ; Heidelberg
- Erscheinungsjahr
- 2024
- Jahrgang
- 28
- Heft
- 4
- Sprache(n)
- Englisch
- DOI
- URL
- Abstract
Purpose:
To investigate whether inexperienced users applying a static navigation system can perform in-vitro a fully guided implant placement protocol and achieve similar results in terms of accuracy compared to experienced clinicians.
Methods:
Based on 36 identical resin models, a computer-assisted implant planning was performed and a surgical guide was produced accordingly. Three study groups were composed with 12 operators, each: control group with experienced surgeons (DOC), test group 1 with dental technicians (TEC) and test group 2 with non-specialists (OFC). Using a fully guided drilling protocol, two implants were placed into each of the 36 models. Subsequently, the differences between the virtually planned and final implant positions were determined and the transfer accuracy was evaluated.
Results:
For the control group DOC, the mean value of axial deviation was 1.90 ± 1.15 degrees, for 3-dimensional deviation at the implant base 0.52 ± 0.33 mm, for 3-dimensional deviation at the implant tip 0.76 ± 0.39 mm and for vertical deviation at the implant tip − 0.11 ± 0.51 mm. For corresponding parameters, the mean values of test group TEC were 1.99 ± 0.87 degrees, 0.42 ± 0.21 mm, 0.68 ± 0.30 mm and − 0.03 ± 0.33 mm and for test group OFC 2.29 ± 1.17 degrees, 0.63 ± 0.35 mm, 0.89 ± 0.43 mm and − 0.24 ± 0.57 mm, respectively. The results did not reveal any statistically significant differences between the control and the 2 test groups (p˃0.05).
Conclusion:
The results of the present in-vitro study demonstrated that inexperienced users applying a static navigation system can perform a fully guided implant placement protocol and achieve similar results in terms of accuracy compared to experienced clinicians in this specific in vitro setup.
- GND-Schlagwort(e)
- ZahnimplantationAnfängerComputerunterstütztes VerfahrenErfahrungswissen
- Freie Schlagwort(e)
- AccuracyExperienceGuided surgeryDental implantStatic navigation
- DDC-Klassifikation
- 610 Medizin, Gesundheit
- RVK-Klassifikation
- YP 5500
- Peer Reviewed
- ja
- Internationale Verbreitung
- ja
- Open-Access-Zeitschrift
- ja
- Dokumenttyp
- Artikel in einer Zeitschrift / Postprint
- URI
- Datum der Freischaltung
- 27.06.2024