Nur-Lesen-Fassung: Das Forschungsinformationssystem (FIS) ist aus Sicherheitsgründen vorübergehend durch diese Nur-Lesen-Fassung ersetzt. Alle öffentlichen Inhalte und Volltexte sind weiterhin abrufbar; Anmeldung, Bearbeitung, Einreichung und Statistiken stehen nicht zur Verfügung. Bei Fragen: fis@uni-bamberg.de

Start › Publikationen › Wearable inertial sensors are highly sensitive in the detection of gait disturbances and fatigue at early stages of multiple sclerosis

Publikation

Wearable inertial sensors are highly sensitive in the detection of gait disturbances and fatigue at early stages of multiple sclerosis

Müller, Roy; Hamacher, Daniel; Hansen, Sascha; u. a. (2021): Wearable inertial sensors are highly sensitive in the detection of gait disturbances and fatigue at early stages of multiple sclerosis, in: BMC Neurology, Berlin ; Heidelberg: Springer, Jg. 21, Nr. 1, S. 1–8, doi: 10.1186/s12883-021-02361-y.

Details

Fakultät/Lehrstuhl
Autorin(nen)/Autor(en)
Müller, Roy
Hamacher, Daniel
Hansen, Sascha
Oschmann, Patrick
Keune, Philipp M.
Titel der Zeitschrift
BMC Neurology
ISSN
1471-2377
Verlagsangabe
Springer : Berlin ; Heidelberg
Erscheinungsjahr
2021
Jahrgang
21
Heft
1
Sprache(n)
Englisch
DOI
Abstract

Background: The aim of the current study was to examine multiple gait parameters obtained by wearable inertial sensors and their sensitivity to clinical status in early multiple sclerosis (MS). Further, a potential correlation between gait parameters and subjective fatigue was explored.

Methods: Automated gait analyses were carried out on 88 MS patients and 31 healthy participants. To measure gait parameters (i.e. walking speed, stride length, stride duration, duration of stance and swing phase, minimal toeto-floor distance), wearable inertial sensors were utilized throughout a 6-min 25-ft walk. Additionally, self-reported subjective fatigue was assessed.

Results: Mean gait parameters consistently revealed significant differences between healthy participants and MS patients from as early as an Expanded Disability Status Scale (EDSS) value of 1.5 onwards. Further, MS patients showed a significant linear trend in all parameters, reflecting continuously deteriorating gait performance throughout the test. This linear deterioration trend showed significant correlations with fatigue.

Conclusions: Wearable inertial sensors are highly sensitive in the detection of gait disturbances, even in early MS, where global scales such as the EDSS do not provide any clinical information about deviations in gait behavior. Moreover, these measures provide a linear trend parameter of gait deterioration that may serve as a surrogate marker of fatigue. In sum, these results suggest that classic timed walking tests in routine clinical practice should be replaced by readily and automatically applicable gait assessments, as provided by inertial sensors.

Freie Schlagwort(e)
Multiple sclerosis (MS)
6-min walk
25 foot walk
toe clearance
motor fatigue
EDSS
DDC-Klassifikation
610 Medizin, Gesundheit
RVK-Klassifikation
YG 6000
Dokumenttyp
Artikel in einer Zeitschrift / Postprint
URI
Datum der Freischaltung
20.10.2025

Permalink: https://fis.uni-bamberg.de/handle/uniba/110881 · Daten als JSON · Zitieren: BibTeX · RIS

Datenstand: 15.11.2026

Eingeschränkter Lesezugriff: Anmeldung, Bearbeitung und Einreichung sind vorübergehend deaktiviert.