Zum Inhalt springen

Nur-Lesen-Fassung: Das Forschungsinformationssystem (FIS) ist aus Sicherheitsgründen vorübergehend durch diese Nur-Lesen-Fassung ersetzt. Alle öffentlichen Inhalte und Volltexte sind weiterhin abrufbar; Anmeldung, Bearbeitung, Einreichung und Statistiken stehen nicht zur Verfügung. Bei Fragen: fis@uni-bamberg.de

Start › Publikationen › Estimation of energy efficiency of heat pumps in residential buildings using real operation data

Publikation

Estimation of energy efficiency of heat pumps in residential buildings using real operation data

Brudermueller, Tobias; Potthoff, Ugne; Fleisch, Elgar; u. a. (2025): Estimation of energy efficiency of heat pumps in residential buildings using real operation data, in: Nature Communications, London: Springer Nature, Jg. 16, Nr. Article number: 2834, S. 1–15, doi: 10.1038/s41467-025-58014-y.

Details

Fakultät/Lehrstuhl
Autorin(nen)/Autor(en)
Brudermueller, Tobias
Potthoff, Ugne
Fleisch, Elgar
Wortmann, Felix
Titel der Zeitschrift
Nature Communications
ISSN
2041-1723
Verlagsangabe
Springer Nature : London
Erscheinungsjahr
2025
Jahrgang
16
Heft
Article number: 2834
Sprache(n)
Englisch
DOI
Abstract

As heat pumps become more prevalent in residential buildings, effective performance monitoring is essential. Design flaws, incorrect settings, and

faults can escalate energy consumption and costs, leading to discrepancies in user expectations and hindering the widespread adoption of this technology crucial for the heating transition.However, field studies using large data sets to offer insights into real-world performance and methods for identifying lowperforming systems in practical, scalable applications are lacking. In the largest field study to date, we analyze sensor data from 1023 heat pumps across Central Europe monitored over two years. Based on existing approaches for controlled laboratory conditions, we derive methods to evaluate and classify real-world performance using operational data. Applying these methods, we find that 17% of air-source and 2% of ground-source heat pumps do not meet existing efficiency standards. Additionally, around 10% of systems are oversized, while approximately 1% are undersized. This underscores the need for standardized post-installation performance evaluation procedures and digital tools to provide actionable feedback for users and installers to enhance operational efficiency and guide future installations.

Freie Schlagwort(e)
-
Peer Reviewed
ja
Internationale Verbreitung
ja
Dokumenttyp
Artikel in einer Zeitschrift / Postprint
URI
Datum der Freischaltung
17.10.2025
Forschungsdaten

Permalink: https://fis.uni-bamberg.de/handle/uniba/110864 · Daten als JSON · Zitieren: BibTeX · RIS

Datenstand: 15.11.2026

Eingeschränkter Lesezugriff: Anmeldung, Bearbeitung und Einreichung sind vorübergehend deaktiviert.