Skip to content

Read-only version: For security reasons, the Research Information System (FIS) has been temporarily replaced by this read-only version. All public content and full texts remain available; login, editing, submission and statistics are not available. Questions: fis@uni-bamberg.de

Home › Publications › Optimization of heating curves for heat pumps in operation : Outdoor temperature ranges for energy-efficient heating curve shifts

Publication

Optimization of heating curves for heat pumps in operation : Outdoor temperature ranges for energy-efficient heating curve shifts

Potthoff, Ugne; Brudermueller, Tobias; Hopf, Konstantin; u. a. (2025): Optimization of heating curves for heat pumps in operation : Outdoor temperature ranges for energy-efficient heating curve shifts, in: Applied Energy, Amsterdam: Elsevier BV, Jg. 389, Nr. 125725, S. 1–21, doi: 10.1016/j.apenergy.2025.125725.

Details

Faculty/Chair
Faculty/Professorship
Author
Potthoff, Ugne
Brudermueller, Tobias
Hopf, Konstantin
Wortmann, Felix
Title of the Journal
Applied Energy
ISSN
1872-9118
Publisher Information
Elsevier BV : Amsterdam
Year of publication
2025
Volume
389
Issue
125725
Language
English
DOI
Abstract

In the light of global sustainability efforts, heat pumps offer environmental benefits, but their complexity and potential misconfigurations often lead to homeowner dissatisfaction due to inaccurate heating and lower-thanexpected efficiency. Among the most important and complex settings is the heating curve and yet there are no easy-to-use methods to optimize it after its initial set-up. This study aims to develop ready-to-use guidelines for optimizing the heating curve with energy-efficient adjustments that improve room comfort and prevent suboptimal user changes, all without requiring additional sensors like room thermostats. Based on interpretable linear models, estimated on 3995 air-to-water heat pumps, located in Central Europe, we select the least energy-intensive heating curve shift for each outdoor temperature, needed to meet room thermal comfort. We find that the standard parallel shift of the heating curve is only the optimal approach when the average outdoor temperature is between 2 ◦ C and 5◦ C. Outside this range, the heating curve should be moved at its starting or the endpoint. Simulation shows that by translating user input to the room controller with our proposed changes, 84.42 % of the heating curves can be improved, reducing the share of misconfigured heating curves from 24.01 % to 7.08 %. This leads to an average reduction in yearly energy consumption of 4.02 % and an increase in the seasonal coefficient of performance by 2.59 % on average. By introducing ready-to-use heating curve improvement guidelines, we aim to increase efficiency and confidence in heat pump technology, ensuring its adoption to meet carbon emission targets.

Keywords
Air-to-water heat pump
Heating curve
Optimization
Residential buildings
Energy efficiency
Operational data
Peer Reviewed
yes
International Distribution
yes
Open Access Journal
no
Type
Article
URI
Activation date
2025-04-02

Permalink: https://fis.uni-bamberg.de/handle/uniba/107299 · Data as JSON · Cite: BibTeX · RIS