Zum Inhalt springen

Nur-Lesen-Fassung: Das Forschungsinformationssystem (FIS) ist aus Sicherheitsgründen vorübergehend durch diese Nur-Lesen-Fassung ersetzt. Alle öffentlichen Inhalte und Volltexte sind weiterhin abrufbar; Anmeldung, Bearbeitung, Einreichung und Statistiken stehen nicht zur Verfügung. Bei Fragen: fis@uni-bamberg.de

Start › Publikationen › Optimization of heating curves for heat pumps in operation : Outdoor temperature ranges for energy-efficient heating curve shifts

Publikation

Optimization of heating curves for heat pumps in operation : Outdoor temperature ranges for energy-efficient heating curve shifts

Potthoff, Ugne; Brudermueller, Tobias; Hopf, Konstantin; u. a. (2025): Optimization of heating curves for heat pumps in operation : Outdoor temperature ranges for energy-efficient heating curve shifts, in: Applied Energy, Amsterdam: Elsevier BV, Jg. 389, Nr. 125725, S. 1–21, doi: 10.1016/j.apenergy.2025.125725.

Details

Fakultät/Lehrstuhl
Autorin(nen)/Autor(en)
Potthoff, Ugne
Brudermueller, Tobias
Hopf, Konstantin
Wortmann, Felix
Titel der Zeitschrift
Applied Energy
ISSN
1872-9118
Verlagsangabe
Elsevier BV : Amsterdam
Erscheinungsjahr
2025
Jahrgang
389
Heft
125725
Sprache(n)
Englisch
DOI
Abstract

In the light of global sustainability efforts, heat pumps offer environmental benefits, but their complexity and potential misconfigurations often lead to homeowner dissatisfaction due to inaccurate heating and lower-thanexpected efficiency. Among the most important and complex settings is the heating curve and yet there are no easy-to-use methods to optimize it after its initial set-up. This study aims to develop ready-to-use guidelines for optimizing the heating curve with energy-efficient adjustments that improve room comfort and prevent suboptimal user changes, all without requiring additional sensors like room thermostats. Based on interpretable linear models, estimated on 3995 air-to-water heat pumps, located in Central Europe, we select the least energy-intensive heating curve shift for each outdoor temperature, needed to meet room thermal comfort. We find that the standard parallel shift of the heating curve is only the optimal approach when the average outdoor temperature is between 2 ◦ C and 5◦ C. Outside this range, the heating curve should be moved at its starting or the endpoint. Simulation shows that by translating user input to the room controller with our proposed changes, 84.42 % of the heating curves can be improved, reducing the share of misconfigured heating curves from 24.01 % to 7.08 %. This leads to an average reduction in yearly energy consumption of 4.02 % and an increase in the seasonal coefficient of performance by 2.59 % on average. By introducing ready-to-use heating curve improvement guidelines, we aim to increase efficiency and confidence in heat pump technology, ensuring its adoption to meet carbon emission targets.

Freie Schlagwort(e)
Air-to-water heat pump
Heating curve
Optimization
Residential buildings
Energy efficiency
Operational data
Peer Reviewed
ja
Internationale Verbreitung
ja
Open-Access-Zeitschrift
nein
Dokumenttyp
Artikel in einer Zeitschrift / Postprint
URI
Datum der Freischaltung
02.04.2025

Permalink: https://fis.uni-bamberg.de/handle/uniba/107299 · Daten als JSON · Zitieren: BibTeX · RIS

Datenstand: 15.11.2026

Eingeschränkter Lesezugriff: Anmeldung, Bearbeitung und Einreichung sind vorübergehend deaktiviert.