Home › Publications › Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement : an in vitro study

Publication

Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement : an in vitro study

Reiff, Florian Sebastian; Bischoff, Charlotte; Woelfler, Henriette; u. a. (2025): Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement : an in vitro study, in: Bamberg: Otto-Friedrich-Universität, S. 1491–1500.

Details

Faculty/Chair
Faculty/Professorship
Author
Reiff, Florian Sebastian
Bischoff, Charlotte
Roehling, Stefan
By
... ; Woelfler, Henriette; ...
Publisher Information
Otto-Friedrich-Universität : Bamberg
Year of publication
2025
Source/Other editions
Oral and Maxillofacial Surgery, 28 (2024), 4, S. 1491–1500. - ISSN: 1865-1569
Year of first publication
2024
Language
English
Licence
URN
Abstract

Purpose:

To investigate whether inexperienced users applying a static navigation system can perform in-vitro a fully guided implant placement protocol and achieve similar results in terms of accuracy compared to experienced clinicians.

Methods:

Based on 36 identical resin models, a computer-assisted implant planning was performed and a surgical guide was produced accordingly. Three study groups were composed with 12 operators, each: control group with experienced surgeons (DOC), test group 1 with dental technicians (TEC) and test group 2 with non-specialists (OFC). Using a fully guided drilling protocol, two implants were placed into each of the 36 models. Subsequently, the differences between the virtually planned and final implant positions were determined and the transfer accuracy was evaluated.

Results:

For the control group DOC, the mean value of axial deviation was 1.90 ± 1.15 degrees, for 3-dimensional deviation at the implant base 0.52 ± 0.33 mm, for 3-dimensional deviation at the implant tip 0.76 ± 0.39 mm and for vertical deviation at the implant tip − 0.11 ± 0.51 mm. For corresponding parameters, the mean values of test group TEC were 1.99 ± 0.87 degrees, 0.42 ± 0.21 mm, 0.68 ± 0.30 mm and − 0.03 ± 0.33 mm and for test group OFC 2.29 ± 1.17 degrees, 0.63 ± 0.35 mm, 0.89 ± 0.43 mm and − 0.24 ± 0.57 mm, respectively. The results did not reveal any statistically significant differences between the control and the 2 test groups (p˃0.05).

Conclusion:

The results of the present in-vitro study demonstrated that inexperienced users applying a static navigation system can perform a fully guided implant placement protocol and achieve similar results in terms of accuracy compared to experienced clinicians in this specific in vitro setup.

GND Keywords
Zahnimplantation
Anfänger
Computerunterstütztes Verfahren
Erfahrungswissen
Keywords
Accuracy
Experience
Guided surgery
Dental implant
Static navigation
DDC Classification
610 Medicine & health
RVK Classification
YP 5500
Peer Reviewed
yes
International Distribution
yes
Open Access Journal
yes
Type
Article
URI
Activation date
2025-01-20

Permalink: https://fis.uni-bamberg.de/handle/uniba/105938 · Data as JSON · Cite: BibTeX · RIS

Data as of: 2026-11-15

Restricted read-only access: login, editing and submission are temporarily disabled.