Zum Inhalt springen

Nur-Lesen-Fassung: Das Forschungsinformationssystem (FIS) ist aus Sicherheitsgründen vorübergehend durch diese Nur-Lesen-Fassung ersetzt. Alle öffentlichen Inhalte und Volltexte sind weiterhin abrufbar; Anmeldung, Bearbeitung, Einreichung und Statistiken stehen nicht zur Verfügung. Bei Fragen: fis@uni-bamberg.de

Start › Publikationen › Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement : an in vitro study

Publikation

Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement : an in vitro study

Reiff, Florian Sebastian; Bischoff, Charlotte; Woelfler, Henriette; u. a. (2025): Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement : an in vitro study, in: Bamberg: Otto-Friedrich-Universität, S. 1491–1500.

Details

Fakultät/Lehrstuhl
Autorin(nen)/Autor(en)
Reiff, Florian Sebastian
Bischoff, Charlotte
Roehling, Stefan
Von
... ; Woelfler, Henriette; ...
Verlagsangabe
Otto-Friedrich-Universität : Bamberg
Erscheinungsjahr
2025
Quelle/Weitere Ausgabe
Oral and Maxillofacial Surgery, 28 (2024), 4, S. 1491–1500. - ISSN: 1865-1569
Jahr der Erstpublikation
2024
Sprache(n)
Englisch
Lizenz
URN
Abstract

Purpose:

To investigate whether inexperienced users applying a static navigation system can perform in-vitro a fully guided implant placement protocol and achieve similar results in terms of accuracy compared to experienced clinicians.

Methods:

Based on 36 identical resin models, a computer-assisted implant planning was performed and a surgical guide was produced accordingly. Three study groups were composed with 12 operators, each: control group with experienced surgeons (DOC), test group 1 with dental technicians (TEC) and test group 2 with non-specialists (OFC). Using a fully guided drilling protocol, two implants were placed into each of the 36 models. Subsequently, the differences between the virtually planned and final implant positions were determined and the transfer accuracy was evaluated.

Results:

For the control group DOC, the mean value of axial deviation was 1.90 ± 1.15 degrees, for 3-dimensional deviation at the implant base 0.52 ± 0.33 mm, for 3-dimensional deviation at the implant tip 0.76 ± 0.39 mm and for vertical deviation at the implant tip − 0.11 ± 0.51 mm. For corresponding parameters, the mean values of test group TEC were 1.99 ± 0.87 degrees, 0.42 ± 0.21 mm, 0.68 ± 0.30 mm and − 0.03 ± 0.33 mm and for test group OFC 2.29 ± 1.17 degrees, 0.63 ± 0.35 mm, 0.89 ± 0.43 mm and − 0.24 ± 0.57 mm, respectively. The results did not reveal any statistically significant differences between the control and the 2 test groups (p˃0.05).

Conclusion:

The results of the present in-vitro study demonstrated that inexperienced users applying a static navigation system can perform a fully guided implant placement protocol and achieve similar results in terms of accuracy compared to experienced clinicians in this specific in vitro setup.

GND-Schlagwort(e)
Zahnimplantation
Anfänger
Computerunterstütztes Verfahren
Erfahrungswissen
Freie Schlagwort(e)
Accuracy
Experience
Guided surgery
Dental implant
Static navigation
DDC-Klassifikation
610 Medizin, Gesundheit
RVK-Klassifikation
YP 5500
Peer Reviewed
ja
Internationale Verbreitung
ja
Open-Access-Zeitschrift
ja
Dokumenttyp
Artikel in einer Zeitschrift / Postprint
URI
Datum der Freischaltung
20.01.2025

Permalink: https://fis.uni-bamberg.de/handle/uniba/105938 · Daten als JSON · Zitieren: BibTeX · RIS

Datenstand: 15.11.2026

Eingeschränkter Lesezugriff: Anmeldung, Bearbeitung und Einreichung sind vorübergehend deaktiviert.